2.15.015 Revisions.
The following sections of the IBC are hereby revised.
Section 101.1 Insert: City of Pullman
IBC Section 105 PERMITS:
105.1 Required. Any owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any gas, mechanical or plumbing system, the installation of which is regulated by the City of Pullman Construction Code, or to cause any such work to be done, shall first make application to the building official and obtain the required permit.
105.1.1 Annual permit for state university.
In lieu of an individual permit for each alteration to existing building interior space or an already approved gas, mechanical or plumbing installation, the building official is authorized to issue an annual permit upon application and approval to any state university located within the city limits. The Building Official is hereby authorized to develop and administer policies for the issuance of annual permits.
105.1.2 Annual permit records.
The state university to which an annual permit is issued shall keep a detailed record of alterations made under such annual permit. The building official shall have access to such records at all times or such records shall be filed with the building official as designated.
Section 1502.1 Roof drainage. Delete ‘International’ and insert ‘Uniform’
Section 1502.2 Secondary (emergency overflow) drains or scuppers. Delete ‘International’ and insert ‘Uniform’
Section 1612.3 Insert: City of Pullman
Section 1612.3 Insert: 5-19-81
Section 1805.4.3 Drainage and discharge. Delete ‘International’ and insert ‘Uniform’
Section 3412.2 Insert: July 17, 1917
The following sections of the IRC are hereby revised.
Section R101.1 Insert: City of Pullman.
Table R301.2(1) Climatic and Geographical Design Criteria
WIND DESIGN |
|||
Speed (mph) 110 |
Topographic effects NO |
Special wind region NO |
Wind-borne debris zone NO |
SEISMIC DESIGN CATEGORY B |
|||
SUBJECT TO DAMAGE FROM |
|||
Weathering Severe |
Frost line depth 30 inches |
Termite Slight |
|
WINTER DESIGN TEMP 2 degrees F. |
|||
ICE BARRIER UNDERLAYMENT REQUIRED Yes |
|||
FLOOD HAZARDS |
|||
May 20, 1969 May 19, 1981 |
5302120001C 5302120002C 5302120003C 5302120004C 5302120005C |
||
AIR FREEZING INDEX 975 |
|||
MEAN ANNUAL TEMP 47.1 degrees F. |
Section 113.1 Delete “Construction Board of Appeals” and insert “Hearing Examiner.” (Ord. 24-02 §1, 2024; Ord. 21-1 §2, 2021; Ord. 16-8 §2, 2016; Ord. 13-16 §3, 2013; Ord. 10-8 §5, 2010; Ord. 08-2 §7, 2008; Ord. 05-2 §23, 2005).